A2 Checking Current Consumption Of Devices - Jacuzzi LED Series Troubleshooting Manual

Hide thumbs Also See for LED Series:
Table of Contents

Advertisement

Verify All 240 VAC Models power connections are as follows:
North American 240 VAC/60 Hz, Fig. D:
Hot to Hot: Measure across test points 1 and 2 for 240 VAC.
Hot to Ground: Measure across test points 1 and 23 for 120 VAC; then across 2 and 23 for 120
VAC.
North American (60 Hz) 240 VAC 3-Wire
A2
Checking Current Consumption of Devices
This table lists current draw for most major hot tub components:
J300 Collection
(North American 60 Hz)
Device
Pump 1 High Speed only
(J-315/J-325 only)
Pump 2 (High speed only)
Heater 1 kW/4 kW (Con-
vertible Models Only)
Heater 5.5 kW
Circulation Pump
CLEARRAY (Standard)
Ozone Generator (Opt)
38
Fig. D
HOT
TB1
RED
HOT
1
1
HOT
BLK
HOT
2
2
to Circuit Board
23
GRN
1- and 2-pump models.
DANGER: Electrical Shock Hazard Exists!
High Voltage Present on Circuit Board. Use
Extreme Caution while Servicing Circuit Board.
Current
Consumption ±10%
9.0A-11.0A
9.0A-11.0A
7.0A-9.0A (120 VAC)
16.7A (240 VAC)
19.5A-23.5A (240 VAC)
0.5A-1.0A
0.4A
0.1A
Fig. E
TB2
1
2
TB1
1
2
GRN
Export (50 Hz) 230 VAC Models
J300 Models (Export 50 Hz)
Device
Pump 1 High speed
Pump 2 (High speed only -
for 2-pump models)
Heater 2.7 kW
Circulation Pump
CLEARRAY (Standard)
Ozone Generator
BLUE
BLUE
BROWN
BROWN
to Circuit Board
Current
Consumption ±10%
6.3A-8.7A
6.3A-8.7A
9.5A-12.5A (230 VAC)
0.3A-0.7A
0.4A
0.1A