Connecting To The Gm1 Controller - Panasonic GM1 User Manual

Motion controller
Hide thumbs Also See for GM1:
Table of Contents

Advertisement

10.6 Connecting to the GM1 Controller

Connect the PC where the GM Programmer is installed to the GM1 Controller.
The connection status of the PC includes "Connected", "Connection as a device user", "Login",
and "Online config mode".
Depending on the connection status, operations that can be executed are different.
If the Controller is provided with a device user registration, connection must be made as the
device user.
Without device user registration
List of available GM1 Controller operations
Function
Setting / acquiring Controller
information
Application management
Reset
Security
Debug
Commissioning
(Note 1)
Not possible to operate the PLC Shell.
(Note 2)
Possible to upload the source.
(Note 3)
Possible to reset the device (PLC initialization) or to delete device application from the device.
(Note 4)
Possible to reset the device (PLC initialization).
WUME-GM1RTXSU-01

10.6 Connecting to the GM1 Controller

Not connected Connected
×
×
(Note 2)
×
×
(Note 3)
×
×
×
×
×
×
×
Login
Online config mode
×
(Note 1)
×
(Note 4)
×
×
×
10-17