2-4-3 Connecting to the Terminal Block of the Controller

● In connection to the terminal block of the controller, mount a single wire or stranded wire (lead
wire) with a ferrule (sleeve) terminal (prepared separately) as shown in the figure below, and
insert it to the back of the hole.
● When it is correctly inserted, it is locked and not removed by pulling. If it is pulled with strong
force, it may be disconnected.
● To connect a stranded wire (lead wire) without using a ferrule (sleeve) terminal, mount it
while holding the release button.
● To disconnect a single wire or stranded wire (lead wire), pull out the single wire or stranded
wire (lead wire) while pressing the release button.
2
● 0.2 to 1.5mm
© Panasonic Industriar Devices SUNX Co., Ltd. 2016
(AWG 24 to 16) is recommend for single wire or stranded wire (lead wire).
Flathead screwdriver
Lead wire
Ferrule (sleeve) terminal
(Purchase separately.)
Release button
Wiring
17