7.5 Monitor Window
NO. Name
(4)
Input signal status monitor
(5)
Internal status monitor
(6)
Pulse sum monitor
Encoder information
(7)
monitor
(Note 1)
Because Ethernet communication is used to transfer data between the servo amplifier and PC, there
is a difference or delay between the value displayed on the screen and the actual value of the servo
amplifier.
(Note 2)
When the polarity is "+", symbol "+" is not displayed.
(Note 3)
The monitor function is not a measuring instrument. Use the values displayed in the Monitor window
as a guide.
(Note 4)
If the servo amplifier outputs "Error 40.0 Error protection from absolute system failure" or "Error
42.0 Error protection from absolute overspeed", execute "Clear Multi-turn". Unless the absolute
encoder is reset, the alarm cannot be cleared.
7-12
Description
Logical Output – Displays the status of signals within the servo amplifier.
Red: Indicates that signal status is active
Pink: Indicates that signal status is inactive
Displays the status of input signals. The tab can be switched between
"Physical Input" and "Logical Input".
Physical Input – Displays the status of input signals to the servo amplifier.
Red: Indicates that COM- is connected
Pink: Indicates that signal status is open
Logical Input – Displays the status of signals within the servo amplifier.
Red: Indicates that signal status is active
Pink: Indicates that signal status is inactive
Displays the internal status of the servo amplifier.
Name
Function
Commanded
Displays the position deviation of a command unit.
position deviation
Actual speed
Displays the monitor speed
Torque command
Displays the torque command.
Displays the ratio relative to the rated load. Adjust
Load factor
the operation pattern so that 100% is not exceeded.
Power supply
Displays the voltage (voltage between the P and N
voltage value
terminals) of power supply to the servo amplifier.
Displays the sum of command and encoder pulses received by the servo
amplifier.
Displays encoder information.
Displays an absolute position when the motor makes
Single-turn data
no more than a single turn.
Displays how many turns the motor made after
Multi-turn data
"Clear" operation.
Clicking "Clear Multi-turn" resets the multi-turn data stored in the encoder to
"0" and clears all encoder errors.
Note: Before using "Clear Multi-turn", check the precautions on use. To clear
encoder errors, you may need to restart the servo amplifier.