CHAPTER 7: ADDITIONAL INFORMATION
TROUBLESHOOTING GUIDE (continued):
Fault D108: Motor
Over Current
Fault D109: Motor
Controller Zero
Current
Fault D110: Motor
Controller Overcurrent
Fault D111: Motor
Controller Voltage
Overload
Fault D112: Motor
Controller
Undervoltage
Fault D113: Motor
Controller Control
Fault
Fault D114: Lower
Board Incline Range
Fault
DC
High Incoming AC Voltage
MCB
DC
Low Incoming AC Voltage
MCB
DC
High Incoming AC Voltage
MCB
DC
Low Incoming AC Voltage
MCB
DC
Low Incoming AC Voltage
MCB
DC
Incline Stall - incline not
MCB
moving when commanded
DC
Incline out of range
MCB
TRUEfitness.com / 800.426.6570 / 636.272.7100
High AC line voltage
Motor Control Board
High Belt Deck
Friction
Low AC Line Voltage
High AC line voltage
Motor Control Board
High Belt Deck
Friction
Low AC Line Voltage
Low AC Line Voltage
Console displays Fault
Calibration not saved.
Incline disabled.
Incline Potentiometer
value out of range
Acme Nut Jammed
Motor bearings
Console displays Fault
Calibration not saved.
Incline disabled.
Incline Potentiometer
value out of range
Check AC line voltage
Power cycle
Contact dealer or
TRUE service
Lubricate treadbelt
Power cycle
Contact dealer or
TRUE service
Check AC line voltage
Power cycle
Contact dealer or
TRUE service
Lubricate treadbelt
Power cycle
Check AC line voltage
Contact dealer or
TRUE service
Power cycle
Check AC line voltage
Contact dealer or
TRUE service
Power cycle
Check cable
Connections
Run incline calibration
Contact dealer or
TRUE service
Power cycle
Check cable
connections
Run incline calibration
Contact dealer or
TRUE service