TROUBLESHOOTING GUIDE (continued):
Fault CN03: Stuck Key
Fault CN04: Lower
Board Comm Fault
(Treadmill Only)
Fault CN05: No Lower
Control
Fault CN06: Config
Mismatch
Fault CN07:
Calibration Timeout
Fault CN08:
Calibration Failed -
Lower Limit Not
Reached
Fault CN09: Insert
Safety Key
Fault CN10: E-Stop
Fault
Membrane Key stuck
Console
down/closed
Brainboard fails to receive
timely communication
Console
responses from lower board -
Fault after 3 retries
No lower board connected to
Console
console - detection wires not
connected.
Console is configured for a
Console
product different than that to
which it is connected.
Incline Calibration was not able
Console
to complete within allowed
time.
During incline calibration, the
Console
incline stalled before reaching
what should be the lower limit.
Console
Emergency Circuit opened
A test of the emergency circuit
Console
has failed
TRUEfitness.com / 800.426.6570 / 636.272.7100
Membrane key is
damaged
Loose Cable
Smart Card
Motor control board
Console
Loose Cable
Console Configure
incorrectly
Console Configure
incorrectly
Loose Cable
Low AC Line Voltage
Console displays Fault
Calibration not saved.
Incline disabled.
Incline Potentiometer
value out of range
Safety Key not
engaged
Loose Cable
Switch Damaged
Console Catch
Safety Key not
engaged
Loose Cable
Switch Damaged
Contact dealer or
TRUE service
Power cycle
Check cable
connections
Contact dealer or
TRUE service
Power cycle
Check cable
connections
Re-configure console
Power cycle
Re-configure console
Check cable
Connections
Retry calibration
Verify AC Voltage at
Outlet
Power cycle
Check cable
connections
Run incline calibration
Contact dealer or
TRUE service
Re-insert safety key
Check cable
Connections
Contact dealer or
TRUE service
Power cycle
Re-insert safety key
Check cable
connections
Contact dealer or
TRUE service
139