Verbose Mode; Symbol Definitions; Error Responses - Extron electronics AXI 22 AT User Manual

Audio expansion interfaces
Hide thumbs Also See for AXI 22 AT:
Table of Contents

Advertisement

Verbose Mode

A USB connection is used to monitor changes that occur on the AXI 22 AT and AXi 44 AT.
For a session to receive change notices, the device must be set to verbose mode 1 or 3. In
verbose mode 1 or 3, the device reports changes in messages that resemble tagged SIS
command responses.
NOTES:
If tagged responses are enabled (verbose modes 2 and 3), all "query" and "view"
commands return the constant string and the value (tagged).
For example, a tagged response to a part number query (N) would return
Pno
If tagged responses are not enabled (verbose modes 0 and 1), all "query" and
"view" commands only return the value without the constant string.
Set command responses are always tagged.

Symbol Definitions

=
]
=
}
=
|
=
E
=
W
=
NOTES:
Only instances marked with a
characters in the command and response tables are only inserted for ease of
reading.
Unless stated otherwise, SIS commands are not case sensitive.

Error Responses

When the device is unable to execute the command, it returns an error response to the
host. The error response codes and their descriptions are as follows:
E10 —
E11 —
E12 —
E13 —
E14 —
X!]
. An untagged response would only return
Carriage return (with line feed)
Carriage return (no line feed)
Space character
Pipe (can be used interchangeably with the
character)
Escape key
Can be used interchangeably with the
character
Unrecognized command
Invalid preset number
Invalid port number
Invalid parameter
Not valid for this configuration
X!]
}
E
character require a space. Any spaces between
E17 —
Invalid command for signal type
E18 —
System/command timed out
E22 —
Busy
E24 —
Privilege violation
E25 —
Device not present
AXI 22 AT and AXI 44 AT • Remote Control
.
31

Advertisement

Table of Contents
loading

This manual is also suitable for:

Axi 44 at

Table of Contents