BBU Status.
the following:
OK
Not Present
disabled using CLI.)
No Battery
Testing
Charging
automatically if the battery voltage falls too low. This normally occurs
about once a week to top off the charge level; the process does not change
the BBU readiness state.
If the battery is ever discharged through a backup cycle or if the system
power is off for more than two weeks, the battery status changes to
"Charging" the next time the system is powered on. This indicates the
BBU is not able to backup the 3ware RAID controller. When the BBU is
in the charging state, write caching is disabled automatically on all units
attached to the controller.
Fault
is outside the acceptable range.
Error
Weak Battery
battery health test or capacity test indicate that the battery is below the
warning threshold (48 hours).
Failed Battery
Battery" status is displayed if the battery failed the health test or the
battery capacity is below the error threshold (24 hours). The battery must
be replaced.
Battery Voltage.
measures and evaluates the battery voltage continuously. If the voltage falls
outside the normal range, warning or error level AENs are generated. In the
case of a voltage error the BBU status will change to "Fault" and the battery
will be disconnected electronically.
Battery Temperature
BBU measures and evaluates the battery pack temperature continuously. If the
temperature falls outside the normal range, warning or error level AENs are
generated based on the measured temperature. In the case of a temperature
error, the BBU status will change to "Fault" and the battery will be
disconnected electronically.
Estimated Backup Capacity.
hours. This is the amount of time that the battery backup unit can protect the
data in the 3ware RAID controller's cache memory. This field is set to zero at
www.3ware.com
Indicates the status of the BBU. Possibly BBU statuses include
. The BBU is functioning normally.
. The BBU was not detected or is disabled. (The BBU can be
. No battery pack is installed in the BBU.
. A battery capacity test is in process.
.The battery is being charged. Charging of the battery occurs
.The BBU detected a fault. This occurs if the voltage or temperature
. Other BBU error. Please contact AMCC Technical Support.
. The battery should be replaced soon.The results of a
. The battery failed a test and must be replaced. A "Failed
Indicates the voltage status of the battery. The BBU
. Indicates the temperature status of the battery. The
Indicates the estimated backup capacity in
3DM 2 Reference
111