Smeg FS9010XS Manual page 32

Hide thumbs Also See for FS9010XS:
Table of Contents

Advertisement

Adjusting the minimum setting for natural
or city gas
Light the burner and turn it to the minimum
position. Extract the gas cock knob and turn
the adjustment screw next to the cock rod
(depending on the model) until the correct
minimum flame is achieved.
Refit the knob and verify that the burner
flame is stable.
Turn the knob rapidly from the maximum to
the minimum setting: the flame should not go
out. Repeat the operation on all gas cocks.
34
Installation
Adjusting the minimum setting for LPG
Tighten the screw located at the side of the
cock rod clockwise all the way.
Lubrication of gas cocks
Over time the gas cocks may become
difficult to turn and get blocked. Clean them
internally and replace the lubrication
grease.
Following adjustment to a gas
other than the one originally set in
the factory, replace the gas setting
label fixed to the appliance with
the one corresponding to the new
gas. The label is inserted inside the
nozzle pack (where present).
The greasing of the gas cocks
should be performed by
authorised persons.