Service and maintenance
9.1
Basic safety information
9.1.1
Maintenance
The device is generally maintenance-free. However, a periodic inspection according to
pertinent directives and regulations must be carried out.
An inspection can include check of:
● Ambient conditions
● Seal integrity of the process connections, cable entries, and cover screws
● Reliability of power supply, lightning protection, and grounds
9.1.2
Impermissible repair of the device
Impermissible repair of the device
● Repair must be carried out by Siemens authorized personnel only.
9.1.3
Penetration of moisture into the device
NOTICE
Penetration of moisture into the device
Device damage
● Make sure when carrying out cleaning and maintenance work that no moisture penetrates
SITRANS LR260 with mA/HART
Operating Instructions, 11/2019, A5E32337683-AD
WARNING
the inside of the device.
9
115