Chilled sparkling
SPARKLING outlet
Command Centre
Carbonation valve flow adjustment
• Use a 6mm Allen key or a
large flat-blade screwdriver
to adjust the valve.
• Rotate the adjustment screw
anti-clockwise to increase,
and clockwise to decrease
the flow.
• To measure the set flow rate, use a measuring jug or cup and run the
sparkling water for 15 seconds. The HydroTap has a default 15 second
dispense time, which will help in your flow rate setup.
• Multiply the amount of water dispensed in 15 seconds by 4 to determine
the flow rate in litres per minute.
• The optimum flow rate is 1.6 litres per minute (400ml per 15 seconds).
• If the flow rate is adjusted too high, the carbonation tank will be emptied
of water, leaving only CO
inconsistent flow (spluttering).
Quick Start Installation Guide
807120NZ v1.00 01.21 G5 C CS Quick Start Guide
Fit the carbonation valve
SECTION 7:
installations
to be dispensed from the tap. This will result in
2
Avoid
-
+
13