II 3066-2

FUSE IN THE IEC CONNECTOR

LINE VOLTAGE
100 V
120 V
220 V
230 V
240 V

COVER PLATE

A COVER PLATE has to be mounted to the housing of the POWER SUPPLY. This PLATE
prevents parts from falling onto PCB A3/4 during a maintenance call or when the operator
opens the SBS TOP COVER for any reason. The COVER PLATE is mounted with 2 PLASTIC
SCREWS (M4x10) to the POWER SUPPLY COVER.

DFT JUMPER

This JUMPER terminates the WIRING HARNESS to the DFT. It simulates a closed
DARK-ROOM FEED TRAY. The SBS is delivered with this JUMPER. If a DFT is to be
installed, this JUMPER is replaced with the SOCKET from the DFT cable. If no DFT is
installed AND if this JUMPER is missing, the SBS BUZZER will sound permanently.

BRIGHTNESS CONTROL PCB

This PCB allows to control the brightness of the DFT INDICATOR LED in the DARKROOM.
To install it, take off CONNECTOR A4X30, plug in the CONNECTOR of the BRIGHTNESS
CONTROL PCB instead and plug in the CONNECTOR A4X30 to the SOCKET on the
BRIGHTNESS CONTROL PCB. See the layout of PCB A4 on the next page.
10/98
EUROPE
—-
—-
T 3.15A (IEC)
T 3.15A (IEC)
T 3.15A (IEC)
NOTE
Install this PCB only if the SBS is used with a DFT
USA / CANADA
—-
T 2A ( SLOW
BLOW)
—-
—-
T 2A (SLOW
BLOW)
5-4
OTHER
COUNTRIES
T 3.15A (IEC)
—-
T 3.15A (IEC)
T 3.15A (IEC)
T 3.15A (IEC)
KODAK AG, Stuttgart