Other Isecure Cloud Web Portal Screens - NAPCO iSecure Installation & Programming Instructions

Professional cellular alarm system
Table of Contents

Advertisement

Other iSecure Cloud Web Portal Screens

GENERAL SETTINGS
Various system settings are available, including those to control
system delays, timeouts, reporting and special system security
codes. Each is described below.
Entry Delay 1
Entry Delay 2
Exit Delay
Separate delays that let you exit and enter your premises without
setting off an alarm when the system is armed. The iSecure sys-
tem has three programmable Entry Delay times available: 30, 45
and 60 seconds (default is 30 seconds). Exit Delay available
times are 45, 60 and 90 seconds (default is 45 seconds).
Door Chime Duration
When Door Chime is enabled, a beep will sound while the system
is disarmed to alert that the programmed zone (for example, an
Entry Door) has been opened. Available times are 1, 1.5 and 2
seconds.
Alarm Siren Timeout
Fire Siren Timeout
Duration the siren will remain active (ON) unless the system is
reset or silenced with a code entry.
Sensor Supv. Timeout
Specifies the length of time before a 319MHz transmitter supervi-
sory trouble is triggered if no transmission is received from the
transmitter. The default Sensor Supv. Timeout upon a Go-
Anywhere Hub Cold Start is "Undefined", but available selections
are 4 and 24 hours.
Enable Remote Hardwired Receiver
Check to allow the use of a GEMWV-RECV wireless receiver in
the system. With 2 integral Hub receivers, this additional receiver
would make a system total of 3. See the installation instructions
supplied with the GEMWV-RECV (WI2316) to configure the re-
ceiver jumpers to enable the GEMWV-RECV as receiver #3.
Report Ambush
Ambush Prefix
Disarming with an Ambush Code will cause a silent report to be
sent to a central station. Thus, should a user be forced to disarm,
the user can silently signal an emergency while appearing to be
merely disarming the system. Add a check to enable Report
56
All technical manuals are available in PDF format at
Ambush, and the Ambush Zone will automatically report. Note:
The Ambush Prefix is a 2-digit code that is entered immediately
prior to (and as part of) a regular valid User Code. Important:
Do not program the first two digits of ANY User Code as the same
digits entered for the "Ambush Prefix".
Report Troubles
Report Arm or Disarm
Disable ALL Reporting
Check Report Troubles to allow all system troubles to be report-
ed to the central station. If Report Troubles is unchecked and
Report Arm or Disarm is checked, only arm/disarm events will
be reported to the central station. If Disable ALL Reporting is
checked, all central station reporting will be stopped.
Enable Base Unit Siren
Check to enable (and uncheck to silence) the Go-Anywhere
Smart Hub sounder and speaker (enabled by default).
Disable Audible System Trouble
Unchecked by default, add a check to silence all audible system
trouble notifications at the Hub and at all keypads.
Master Security Code
This code is added to the Go-Anywhere Hub memory at the facto-
ry and is not changeable. This code is printed on a label placed
on a card (OI404LF) that is included with the Go-Anywhere Hub.
Entering this code at a keypad will provide access to ALL func-
tions in the system. This code MUST be entered in this field and
must match the code at the corresponding Hub. Note: All key-
pad programming must be performed at the keypad addressed as
Keypad # 1. Retain the OI404LF card with the code in a secure
place for reference. Note: Whenever you add or update the
Master Security Code, you must log out and log back into the ap-
plication (exiting and re-entering ensures that the iSecure Cloud
Web Portal and the Master Security Code are synchronized and
the system is fully protected by your secure account password).
Download Security Code
This code is not a keypad code, but is only used to permit local or
remote connections to be established between the iSecure Cloud
Web Portal and the Go-Anywhere Hub. Used during the connec-
tion process, if the code stored in the Hub does not match the
code entered here (in the iSecure Cloud Web Portal), a data con-
nection will be denied. Some dealers with multiple iSecure Cloud
Web Portal accounts use the same Download Security Code for
all accounts. When attempting to establish a connection, if this
code is forgotten, the Master Security Code of the particular Go-
Anywhere Hub can be used in its place.
Dealer Keypad Programming Code
This code is left blank in the Hub memory at the factory and may
be added by the dealer (in possession of the Master Security
Code). The Dealer Keypad Programming Code allows the
same access to programming functions as the Master Security
Code.
Bell Supervision
If checked, the Bell output, supervised with an EOLR, if shorted or
opened the keypad will display an E51 trouble, with a report sent
to the central station.
Auto Reset Trouble Disable
If this feature is checked (where "auto reset" is to be "disabled"), if
the system detects a trouble and its condition is subsequently
tech.napcosecurity.com
Napco iSecure Security System

Hide quick links:

Advertisement

Table of Contents