OPERATING GUIDE for your
NAPCO FREEDOM
F-64TPG Garage Touchpad
Home Security System
SYSTEM READY
10/15/06
12:05PM
R
Freedom F-64TPG Touchpad
© NAPCO 2006
PATENTED
OI320A 9/06
1

Advertisement

Table of Contents
loading

Summary of Contents for NAPCO F-64TPG

  • Page 1 OPERATING GUIDE for your NAPCO FREEDOM F-64TPG Garage Touchpad Home Security System SYSTEM READY 10/15/06 12:05PM Freedom F-64TPG Touchpad © NAPCO 2006 PATENTED OI320A 9/06...
  • Page 2: Introduction

    Congratulations on your purchase of a new Freedom Garage Door Security Sys- tem. This revolutionary new concept in residential security makes using your sys- tem easier than ever before possible, be- cause the system uses its computerized control panel to continually monitor the status of your garage door.
  • Page 3: Table Of Contents

    TABLE OF CONTENTS INTRODUCTION... 2 TESTING THE SYSTEM... 2 GARAGE TOUCHPAD INDICATORS AND CONTROLS ... 4 ARMING WHEN LEAVING ... 6 BYPASSING FAULTED ZONES ... 7 ARMING STAY: PROTECTING YOURSELF AT HOME... 8 ARMING AND LEAVING WITH OTHERS STAYING ... 9 EXITING WITH THE SYSTEM ALREADY ARMED ...
  • Page 4: Garage Touchpad Indicators And Controls

    F - 6 4 T P G T O U C H P AD C O N T R O L S & I N D I C AT O R S BYPASS SYSTEM READY FIRE FIRE TBL 10/15/06 12:05PM SYS TBL...
  • Page 5 F - 6 4 T P G T O U C H P AD C O N T R O L S & I N D I C AT O R S LCD Window – 32 character LCD displays system status messages, descriptions, system troubles, etc.
  • Page 6: Arming When Leaving

    If you are leaving with no other family members remaining home: Check the Touchpad indicators. The green display will read "SYSTEM READY", indicating that the system is ready to arm. SYSTEM READY • If the green STATUS light is off and zones are scrolling in the display, a perimeter zone is faulted or a monitored deadbolt (other than your exit door) is unlocked.
  • Page 7: Bypassing Faulted Zones

    B Y P AS S I N G F A U L T E D Z O N E S If you are trying to arm with a faulted zone or zones, the LCD display will clearly indicate which zone(s) are faulted. If you cannot repair the zone(s), they may be temporarily removed from the system, or bypassed, using the following procedure: Press the BYPASS button.
  • Page 8: Arming Stay: Protecting Yourself At Home

    A R M I N G S T A Y : P R O T E C T I N G Y O U R S E L F AT H O M E Arming in the Stay mode allows you to remain home with the perimeter protection active but with the interior protection off, so that you may move freely within the premises.
  • Page 9: Arming And Leaving With Others Staying

    A R M I N G AN D L E AV I N G W I T H O T H E R S S T A Y I N G If you are arming and leaving with other family members remaining home: Check the Touchpad indicators.
  • Page 10: Exiting With The System Already Armed

    E X I T I N G W I T H T H E S Y S T E M AL R E A D Y A R M E D If the system is Armed STAY and you are leaving with other family members remaining home: Press the STAY button.
  • Page 11 E X I T I N G W I T H T H E S Y S T E M AL R E A D Y A R M E D If the system is Armed STAY and you are leaving with NO other family members remaining home: Press the AWAY button.
  • Page 12: Emergency Buttons

    Emergency Buttons (Only available if programmed). The Emergency Buttons, if programmed, are always active, whether the system is armed or disarmed. The Emergency Button must be Held Down for 2 seconds to activate the emergency alarm and transmit the signals to central station. E M E R G E N C Y B U T T O N S Fire Emergency Hold down the Fire button to alert the central station of a fire...
  • Page 13: Disarming The System

    D I S AR M I N G T H E S Y S T E M DISARMING WHEN RETURNING HOME: When returning home, open your garage door from the outside to automatically disarm the system. The red ARMED light turn off and the green STATUS light will turn on. If an alarm has occurred while you were away, opening the garage door will initiate an entry delay sequence.
  • Page 14: Silencing An Alarm

    If an alarm occurs while you are at home: The Touchpad siren will sound and the red ALARM "ALARM". Proceed with caution! If you suspect that an intruder may still be in the premises, leave immediately and call authorities from a neighbor's telephone. To silence the alarm, insert your I-FOB key into the I-FOB slot on the face of the Touchpad and re- move when alarm has silenced.
  • Page 15: Fire Protection

    If a fire is detected, the siren will sound a distinct pulsating tone and the LCD window will flash the FIRE word FIRE. If a Fire Alarm does occur: If a fire is in progress, evacuate the premises immediately! Call the Fire Department from an outside phone. If there is no evidence of a fire, press The siren will silence, and the word FIRE in the Touchpad LCD window will stop flashing.
  • Page 16 Preparing a Fire Escape Plan Even with the most advanced fire alarm system, adequate protection requires an escape plan. To prepare your plan, draw floor plans of your building. Show two exits - a front or back door and a window from each room.
  • Page 17: Touchpad Menu Mode

    The Touchpad can provide access to a wide assortment of utility functions, each displayed on the Touchpad LCD window in a prompting “YES/NO” format. 1 To enter Touchpad Menu Mode, press MENU. 2 To skip a function, press NO. 3 To select and execute a function, answer YES. •...
  • Page 18 CHANGE KEYPAD BEEP VOLUME CHANGE VOICE VOLUME ACTIVATE SIREN TEST DISPLAY FIRE ALARM DISPLAY FIRE TROUBLE T O U C H P AD M E N U M O D E continue to chime when system is armed. CHANGE KEYPAD BEEP VOLUME - When the Touchpad buttons are pressed or when an entry warning activates, the Touchpad beeper sounds.
  • Page 19 T O U C H P AD M E N U M O D E ACTIVATE FAULT FIND - Activates a multiple diagnostic test report. For installer's use ACTIVATE only. If accidentally enabled, press RESET to exit. Note: This selection only appears FAULT FIND with a Master I-FOB inserted in the Touchpad.
  • Page 20 ACTIVATE DOWNLOAD ACTIVATE LOST KEY MODE Y/N ACTIVATE PIR TEST T O U C H P AD M E N U M O D E ACTIVATE DOWNLOAD - For installer's use only. If accidentally enabled, press RESET to exit. Note: This feature is disabled while armed. Note: This selection only ap- pears with a Master I-FOB inserted in the Touchpad.
  • Page 21: User Program Mode

    User Program Mode Your Installer has programmed into your system a uniquely coded digital Master I-FOB that can be used to not only disarm the system and silence the siren, but also allows access to the User Program Mode. User Program Mode allows you to program various options, such as adding other User Codes, setting the system Time and Date, enrolling new I-FOB's, etc.
  • Page 22 CREATE MASTER I-FOB CREATE USER I-FOB U S E R P R O G R A M M O D E to the right. 2. Repeat this process to increment (or decrement) the minute as needed. Press EN- TER move the cursor to the right and press the YES or NO buttons to toggle between "A"...
  • Page 23 DELETE I-FOB U S E R P R O G R A M M O D E to the system. Create a User I-FOB as follows: 1. Obtain a new I-FOB from your security professional (order part F-IFOB). 2. With “CREATE USER I-FOB Y/N” displayed in the LCD window, press "Y" and the LCD window will request to insert the new I-FOB into the Touchpad.
  • Page 24: System Trouble Error Codes

    S Y S T E M T R O U B L E E R R O R C O D E S Your control panel is capable of detecting a variety of troubles that may affect system performance. In the unlikely event that a problem should occur, the SYS TBL (system trouble) icon will display on the left side of Touchpad window along with one or more of the following error codes.
  • Page 25 S Y S T E M T R O U B L E E R R O R C O D E S Trouble System Trouble Indication Condition Wireless Transmitter A problem has been detected with a wireless transmitter. Call installing company for service E04-NN Supervisory Failure E05-NN...
  • Page 26 S Y S T E M T R O U B L E E R R O R C O D E S Trouble System Trouble Indication Condition E10-NN Touchpad Response Failure Call installing company for service. Touchpad Tamper E11-NN E12-NN Expansion Zone Module Response Failure...
  • Page 27 S Y S T E M T R O U B L E E R R O R C O D E S Trouble System Trouble Indication Condition E19-00 User Program Memory Call installing company for service. Error E20-00 Dealer Program Call installing company for service.
  • Page 28 S Y S T E M T R O U B L E E R R O R C O D E S Trouble System Trouble Indication Condition E40-00 RF Self Test Failure Fire Trouble E41-NN Bell/Siren Trouble E51-00 E58-00 Telemetry Trouble E59-00 Telemetry Failure...
  • Page 29: User I-Fob List

    • The space below is for recording the names of those in possession of User I-FOB's in your system. If an I-FOB is lost, be sure to delete its I-FOB number from the system (using the procedure on the previous page) as soon as possible. I-FOB Number Area U __ __...
  • Page 30: Lost Garage Door Opener Mode

    L O S T G AR AG E D O O R O P E N E R M O D E Lost Opener Mode In the event that your garage door remote control (or key that operates your garage door opener) is lost or stolen, the system may still be used by arming in the Lost Garage Door Opener Mode.
  • Page 31: Fcc Part 68 Statement

    FEDERAL COMMUNICATIONS COMMISSION (FCC) Part 68 STATEMENT This equipment complies with Part 68 of the FCC rules. On the front cover of this equipment is a label that contains, among other information, the FCC registration number and ringer equivalence number (REN) for this equipment. If requested, this infor- mation must be provided to the telephone company.
  • Page 32: Limitations Of This Alarm System

    While this system is an advanced design security system, it does not offer guaranteed protection against burglary or fire or other emergency. Any alarm system, whether commercial or residential, is subject to compromise or failure to warn for a variety of reasons.
  • Page 33 WARNING! THE LIMITATIONS OF THIS ALARM SYSTEM (Continued) • Even if the system responds to the emergency as intended, however, occupants may have insufficient time to protect them- selves from the situation. In the case of a monitored alarm system, authorities may not respond appropriately. •...
  • Page 34: Limited Warranty

    NAPCO LIMITED WARRANTY NAPCO SECURITY SYSTEMS, INC. (NAPCO) warrants its products to be free from manufacturing defects in materials and workmanship for thirty-six months following the date of manufacture. NAPCO will, within said period, at its option, repair or replace any product failing to operate correctly without charge to the original purchaser or user. This warranty shall not apply to any equipment, or any part thereof, which has been repaired by others, improperly installed, improperly used, abused, altered, damaged, subjected to acts of God, or on which any serial numbers have been altered, defaced or removed.
  • Page 35 written, are either merged herein or are expressly cancelled. NAPCO neither assumes, nor authorizes any other person purporting to act on its behalf to modify, to change, or to assume for it, any other warranty or liability concerning its products. In no event shall NAPCO be liable for an amount in excess of NAPCO's original selling price of the product, for any loss or damage, whether direct, indirect, incidental, consequential, or otherwise arising out of any failure of the product.
  • Page 36: Fcc Part 15 Statement

    THE FOLLOWING STATEMENT IS REQUIRED BY THE FCC This equipment has been tested and found to comply with the limits for a Class-B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio-frequency energy and, if not installed and used in accordance with the instruc- tions, may cause harmful interference to radio communications.
  • Page 37 NOTES...
  • Page 38 NOTES...
  • Page 39 NOTES...
  • Page 40 333 Bayview Avenue Amityville, New York 11701 For Sales and Repairs, (800) 645-9445 For Technical Service, (800) 645-9440 Publicly traded on NASDAQ Symbol: NSSC © NAPCO 2006...