What to do if a fault occurs:

If something is wrong, begin by working through
the following checklist:
Is the power on?
The main switch ( 7) must be set to 1 and the
green lamp on the control panel should be lit or
flashing.
Are the group fuses and main building fuses
OK?
If the switches are on and the green lamp is not lit,
a fuse may have blown. Check and replace the
fuse if necessary.
Is the control panel unlit?
Press the miniature circuit breaker (MCB) on the
electric box ( 5) once. If the control panel goes off
again contact your service engineer. Also check
that the manual operation switch is off ( 6).
Is the display flashing?
This is not a fault. It is part of the control unit's
monitoring function.
Are the radiators cold despite the plant being
switched on?
Check that the radiators are properly vented, turn
off the plant using the main switch when venting.
Vent the heat pump with the venting nipple ( 20)
located on the side of the hot water safety valve.
Open the nipple a couple of turns until water
comes out. Close the nipple afterwards. If one or
more of the radiators are still cold contact the
plumber.

Operational disturbances

27
20
USER
5
6
7
IVT 495 TWIN 9518799