Power supply unit (PSU)

The standard server configuration includes a single, auto ranging 460-watt power supply unit (PSU)
with power factor correction (PFC). The server can be upgraded by replacing the standard PSU with a
redundant power supply (RPS) unit.
WARNING:
Note the following reminders to reduce the risk of personal injury from electric shock
hazards and/or damage to the equipment.
Installation of the power supply unit should be referred to individuals who are qualified to service server
systems and are trained to deal with equipment capable of generating hazardous energy levels.
DO NOT open the power supply unit. There are no serviceable parts inside the power supply unit.
WARNING:
To prevent possible personal injury and damage to system components, HP
recommends performing this procedure with the server placed on its side with the open side up.

Removing a PSU

To remove the PSU, proceed as follows:
Power down the server.
1.
Disconnect the power cord.
2.
Unlock the server if necessary and remove the access panel (refer to the section "System
3.
covers.")
Remove the air baffle as described in the section "Removing a processor."
4.
Place the server on its side with the open side up.
5.
Disconnect all power supply cables from the system board, mass storage devices, and/or
6.
backplane.
Remove the eight mounting screws that secure the PSU to the rear chassis panel.
7.
WARNING:
The PSU is heavy and can cause personal injury or damage system components.
Figure 3-416
Removing the PSU mounting screws
Slightly lift up the power supply and then push toward the front of the chassis until it clears the
8.
support ledge.
Tilt the power supply toward processor 1 and carefully remove it from the chassis.
9.
All manuals and user guides at all-guides.com
Removal and replacement procedures 68