System fans

The server includes four system fan assemblies; three front fan holder assemblies and a rear fan
assembly.

Fan holder assembly removal and replacement

To remove the front fan/PCI card holder assembly:
Power down the server.
1.
Disconnect the power cord(s).
2.
Unlock the server if necessary and remove the access panel as described in the section "System
3.
covers."
Remove all full-size expansion cards as described in the section "Removing an expansion card"
4.
if necessary.
On the front fan holder assembly, press the thumb lever down slightly (Figure 3-40, 1) and slide
5.
the assembly a short distance toward the top of the server chassis (Figure 3-40, 2).
Figure 3-40
Removing the front fan/PCI card holder assembly
Rotate the fan assembly toward the rear of the chassis and lift away from the mounting slots, but
6.
not completely from the chassis.
While supporting the fan holder assembly with one hand, disconnect the fan cable from system
7.
board connector (Figure 3-40, 3).
Remove the front fan holder assembly from the chassis.
8.
End of procedure.