ActionTec V2000H Manual page 93

Table of Contents

Advertisement

Actual Delay (ms) = 7 8
Line Attenuation (dB) = 13.7 15.3
Loop Estimate
Equivalent Gauge = Generic26AWG
Equivalent Loop Length (meters) = 395
Number of Bridged Taps = 0
Bridged Tap 1 (meters) = N/A
Bridged Tap 2 (meters) = N/A
Tap Search Range (meters) = 5.0 - 261.0
Confidence level (%) = 100
Data Rate Reduction (Downstream Actuals)
Crosstalk (kbps) = 12500
AM and NB (kbps) = 1500
Bridged Tap (kbps) = 0
Estimated Data Rates
(using loop estimate above and -122 dBm/Hz noise floor):
DownStream @ VDSL2 DERQ (kbps) = 65616
IPMax-to-Subscriber's Modem DS SNR Margin of 15.0, is greater than or equal
to the threshold of 6db
IPMax-to-Subscriber Modem DS Attenuation of 15.3, is less than or equal to
the threshold of 26db
IPMax-to-Subscriber Modem sync rate passed
Metallic Loop Test
Step 4 of 4
DC-Voltage TG -0.0 Volts
DC-Voltage RG -0.0 Volts
DC-Voltage RT -0.3 Volts
DC Voltage okay.
AC-Voltage TG -1 Volts
AC-Voltage RG -1 Volts
AC-Voltage RT -1 Volts
AC Voltage okay.
Resistance TG OR Kohms
Resistance RG OR Kohms
Resistance RT 599.637 Kohms
Resistance okay.
Capacitive Loop Length = 477.3226 m
Capacitive Balance 92.9%
Loop Capacitive Balance okay.
Loop length okay.
No load coils detected.
Subscriber's Modem detected.
**Summary Statement=All tests passed. If trouble still exists, troubleshoot
CPE and customer configuration. Please check detailed results for Bridged
Taps.**
**Sommaire=Tous les tests complétés avec succès. Si le problème persiste,
investiguer le CPE et la configuration chez le client.**