Figure 25: ADSL Connection Block on top of Feeder/Distribution
Test Clip at the SAC
MS2 4047A Pair Test Plug Assembly (with tool dish).
Every SAC should have a test plug for you to use to monitor or test the
individual pairs.
You would simply insert this test plug into the binding post on the block.
Note – due to the years of usage, this plug may become defective. The leads on the clip becomes
corroded and may give you noise on the line resulting in false readings. Your instructor will show you
alternative way to test the MS2 modular blocks.
Cross Connect Box
Normally inside we would only find 1 row for Feeder and 1 row for Distribution.
These can be pole mounted to service a smaller neighborhood.
MS2 Impact Insertion tools
3M™ Impact Insertion Tool.
The only tool approved for use in connecting jumper wire to MS²™ Quick-Connect modules.
Figure 26: Cross Connect Box
Page 27 of 130