Replacing The Dvd/Dvd-Rw Drive - Fujitsu PRIMERGY TX150 S5 Service Supplement Manual

Hide thumbs Also See for PRIMERGY TX150 S5:
Table of Contents

Advertisement

Replacing the DVD/DVD-RW drive

Ê Pull the operating panel module out of its bay as far as it is possible to get
access to the cable tie.
Ê Thread the two cables through the cable tie.
Ê Take the operating panel module out of its bay.
Ê Push the new operating panel module into its bay as far as it is possible to
have access to the cable tie.
Ê Thread the two cables through the cable tie.
Ê Push the operating panel module into its bay as far as it is possible to plug
the cables.
Ê Connect the ribbon cable and the USB cable to the operating panel board
(see the board layout on
Ê Push the operating panel module into the housing until it engages.
Ê Close the server and connect all power plugs (for a detailed description see
the Options Guide).
4.3
Replacing the DVD/DVD-RW drive
In the basic configuration the top 5.25-inch bay of the accessible drives is
occupied with a DVD/DVD-RW drive.
Ê Open the server and remove the front cover / rack front cover as described
in the
section "Preparation" on page
Ê Remove the power and the data cable at the rear side of the DVD/DVD-RW
drive.
20
page
43).
17.
Service Supplement
Replacement routines