6. Place lag washer, rubber bush, washer onto the lag bolts, as shown.
Thread on the hex nuts and tighten with a 19mm spanner or wrench.
Place a level across the rim to ensure the toilet is flat.
If the pan is not level, loosen the nuts, adjust toilet pan and tighten
the nuts again until satisfactory.
7. Remove the two screws on the right-hand side
of the toilet and remove the side panel.
Remove the 3 remaining screws and remove
the junction box cover.
8. Feed the power cord through the rubber gasket
from the wall and connect to the junction box.
NOTE: Wiring order shall be L, N, Ground from
top to bottom.
Kohler Co.
March 2016
L - Live wire
N - Neutral wire
- Grounding wire