288.03 Sensor (diverter gate) static jam (to top bin) C

Step
Check
1
Check the sensor (diverter gate) for correct operation.
Perform the sensor (diverter gate) test.
1. Enter Diagnostics mode.
2. Select FINISHER TESTS.
3. Select Sensor Tests.
4. Select Media Path2.
5. Select Diverter gate.
Open the finisher front door.
Move the lower media guide assembly to the right.
Insert a sheet of white media beneath the media
diverter gate. Then push the media to the sensor
(diverter gate).
Does the operator panel display change each time a
piece of media is placed at the front of the sensor
(diverter gate)?
2
Check the sensor (diverter gate) connection.
Is the above senor connected properly?
3
Check the drive motor (entrance/paddle) by opening
the finisher front door assembly and then closing it.
Does the motor (entrance/paddle) rotate normally?
4
Is the drive motor (entrance/paddle) connected
properly?
5
Perform a test print.
Does the error still occur?
Yes
No
Go to step 3.
Go to step 2.
Replace the
Replace the
sensor (diverter
connection.
gate). Go to
"Sensor
(diverter gate)
removal" on
page
4-110.
Go to step 5.
Go to step 4.
Replace the drive
Replace the
motor (entrance/
connection.
paddle). Go to
"Drive motor
(entrance/
paddle) and belt
(entrance/
paddle)
removal" on
page
4-100.
Replace the
Problem solved.
finisher controller
card assembly.
Go to
"Finisher
controller card
assembly
removal" on
page
4-118.