Sensor (Finisher Media Entrance) Static Jam A - Lexmark w850 Service Manual

Hide thumbs Also See for w850:
Table of Contents

Advertisement

4024-XXX
Step
Check
8
Is the bridge unit drive motor connected properly?
9
Perform a test print.
Does the error still occur?
10
Perform a test print.
Does the error still occur?

282.01 Sensor (finisher media entrance) static jam A

Step
Check
1
Check the sensor (finisher media entrance) for correct
operation.
Perform the sensor (finisher media entrance) test.
1. Enter Diagnostics mode
2. Select FINISHER TESTS.
3. Select Sensor Tests.
4. Select Media Path1.
5. Select Fin media ent.
Detach the finisher from the printer.
Insert a sheet of white media into the finisher media
path entrance.
Does the display change, every time a piece of white
media is placed over the sensor (finisher media
entrance)?
2
Check the sensor (finisher media entrance)
connection,
Is the above sensor connected correctly?
2-22
Finisher Service Manual
Yes
No
Replace the
Replace the
bridge unit drive
connection.
motor. Go to
"Bridge unit
drive motor
assembly
removal" on
page
4-13.
Replace the
Problem solved.
bridge unit
interface card
assembly. Go to
"Bridge unit
interface card
assembly
removal" on
page
4-117.
Go to step 10.
Replace the
Problem solved.
finisher controller
card assembly.
Go to
"Finisher
controller card
assembly
removal" on
page
4-118.
Yes
No
Go to step 3.
Go to step 2.
Replace the
Replace the
sensor (finisher
connector.
media entrance).
Go to
"Sensor
(finisher media
entrance)
removal" on
page
4-98.

Advertisement

Table of Contents
loading

Table of Contents