Sensor (Bridge Unit Media Entrance) Static Jam B - Lexmark w850 Service Manual

Hide thumbs Also See for w850:
Table of Contents

Advertisement

Step
Check
4
Check the bridge unit drive motor connection.
Is the above motor connected properly?
5
Perform a test print.
Does the error still occur?
6
Perform a test print.
Does the error still occur?

280.02 Sensor (bridge unit media entrance) static jam B

Step
Check
1
Check the sensor (bridge unit media entrance) for
correct operation.
Perform the sensor (bridge unit media entrance) test.
1. Enter Diagnostics mode.
2. Select FINISHER TESTS.
3. Select Sensor Tests.
4. Select Media Path1.
5. Select Bridge media ent.
Open the bridge unit top cover assembly.
Does the display on the operator panel change every
time the actuator of the sensor (bridge unit media
entrance) is operated?
2
Check the sensor (bridge unit media entrance)
connection
Is the above sensor connected properly?
Yes
No
Replace the
Replace the
bridge unit drive
connection.
motor. Go to
"Bridge unit
drive motor
assembly
removal" on
page
4-13.
Replace the
Problem solved.
bridge unit
interface card
assembly. Go to
"Bridge unit
interface card
assembly
removal" on
page
4-117.
Replace the
Problem solved.
finisher controller
card assembly.
Go to
"Finisher
controller card
assembly
removal" on
page
4-118.
Yes
No
Go to step 3.
Go to step 2.
Replace the
Replace the
sensor (bridge
connection.
unit media
entrance). Go to
"Sensor (bridge
unit media
entrance)
removal" on
page
4-16.
Diagnostic information
4024-XXX
2-13

Advertisement

Table of Contents
loading

Table of Contents