Table 24. Environmental specifications (continued)
Type
Condition
Operating
Storage
Maximum Shock
Operating
Storage
Maximum Altitude
Operating
Storage
Operating Altitude De-rating
Up to 35 °C (95 °F)
35 °C to 40 °C (95 °F to 104 °F)
40 °C to 45 °C (104 °F to 113 °F)

Particulate and gaseous contamination specifications

The following table defines the limitations that help avoid any equipment damage or failure from particulates and gaseous
contamination. If the levels of particulates or gaseous pollution exceed the specified limitations and result in equipment damage
or failure, you may need to rectify the environmental conditions. Re-mediation of environmental conditions is the responsibility
of the customer.
This section defines the limits to help avoid IT equipment damage and/or failure from particulates and gaseous
NOTE:
contamination. If it is determined that levels of particulates or gaseous pollution are beyond the limits specified in the
following table and are the reason for the damage and/or failures to your equipment, it may be necessary for you to
re-mediate the environmental conditions that are causing the damage and/or failures. Re-mediation of environmental
conditions will be the responsibility of the customer.
Table 25. Particulate contamination specifications
Particulate contamination
Air Filtration
Applies to data center environments only. Air filtration
NOTE:
requirements do not apply to IT equipment designed to be used
outside a data center, in environments such as an office or
factory floor.
Conductive Dust
Applies to data center and non-data center
NOTE:
environments.
Corrosive Dust
Applies to data center and non-data center
NOTE:
environments.
36
Technical specifications
Temperature or Specification
0.26 G
at 5 Hz to 350 Hz (all operation orientations).
rms
1.88 G
at 10 Hz to 500 Hz for 15 minutes (all six sides
rms
tested).
Six consecutively executed shock pulses in the positive
and negative x, y, and z axes of 40 G for up to 2.3 ms.
Six consecutively executed shock pulses in the positive
and negative x, y, and z axes (one pulse on each side of
the system) of 71 G for up to 2 ms.
3,0482000 m (10,0006560 ft)
12,000 m (39,370 ft)
Maximum temperature is reduced by 1 °C/300 m (1
°F/547 ft) above 950 m (3,117 ft).
Maximum temperature is reduced by 1 °C/175 m (1
°F/319 ft) above 950 m (3,117 ft).
Maximum temperature is reduced by 1 °C/125 m (1
°F/228 ft) above 950 m (3,117 ft).
Specifications
Data center air filtration as defined by ISO Class 8 per
ISO 14644-1 with a 95% upper confidence limit.
Air entering the data center must have
NOTE:
MERV11 or MERV13 filtration.
Air must be free of conductive dust, zinc whiskers, or
other conductive particles.
● Air must be free of corrosive dust.
● Residual dust present in the air must have a
deliquescent point less than 60% relative humidity.