Fusing Temperature Control; Temperature Control - Konica Minolta bizhub 160 Service Manual

Hide thumbs Also See for bizhub 160:
Table of Contents

Advertisement

Theory of Operation Ver. 1.0 Apr. 2005

12.2 Fusing Temperature Control

12.2.1
Temperature Changes (Plain Paper Having a Length of 186 mm or More)
Warm-up
200 °C
130 °C
Power OFF, Front
Door open/close
Mode before
temperature
control
12.2.2

Temperature Control

• The fusing temperature is increased to a predetermined level during the warm-up cycle.
• The warm-up control is provided when power is turned ON, the Front Door is opened and
closed, and the Energy Save mode is canceled.
• In the standby state, the fusing temperature is set to a level (130 °C) lower than that dur-
ing a print cycle, thereby cutting down power consumption.
• The temperature control mode when the control is resumed (when power is turned ON,
the Front Door is opened and closed, or the Energy Save mode is canceled) is set
according to the mode and the fusing temperature valid before the interruption.
• In the Energy Save mode, the Fusing Roller Heater Lamp is turned OFF to reduce power
consumption.
Mode 0:
Mode 1:
180 sec.
300 sec.
Less than 50 °C
Mode 0
Mode 0
Mode 1
Mode 1
Mode 2
Mode 3
Temperature detected by Thermistor
Mode 2:
208 sec.
Thermistor-detected temperature
at temperature control start
50 °C to 125 °C
Mode 0
Mode 2
Mode 1
Mode 2
12. Fusing section
During print cycle
(600 dpi)
In standby
Mode 3
125 °C or more
Mode 0
Mode 3
Mode 3
37

Advertisement

Table of Contents
loading

This manual is also suitable for:

Bizhub 160fBizhub 161Bizhub 161fA0xy026

Table of Contents