17. Fusing section
17.3.2
Fusing temperature control
• A thermistor is used to detect the surface temperature of the Heating Roller. The Heater
Lamp (H1) is then turned ON and OFF as necessary to achieve the set temperature.
Temperature control during monochrome printing (Plain paper)
Power Switch ON
Fusing Ready Temperature
[1]
185
180
174
169
167
100
60
Approx. 45 sec.
[1] During warm-up
Heat the Heating Roller temperature to
178 °C in average 45 seconds.
(100 V – 120 V area)
Heat the Heating Roller temperature to
178 °C in average 49 seconds.
(220 V – 240 V area)
[2] In standby state
Heating Roller temperature setting: 180 °C
*a: If the Heating Roller temperature is 60 °C
or less when the warm-up cycle is started,
temperature control is performed with the
Heating Roller temperature setting changed
to 185 °C. (5 min.)
After the lapse of the 5 min. period, the tem-
perature stabilizes at 180 °C.
60
Copy/Print Start
[2]
[*a]
[*b]
Warm-up completed (approx.70 seconds for 100 V area)
(approx.75 seconds for 200 V area)
Theory of Operation Ver. 1.0 Nov. 2005
[3]
[3] During a print cycle
Heating Roller temperature setting: 169 °C
*b: If the Temperature/Humidity Sensor (TEM/
HUMS) detects a temperature of less than
20 °C, temperature control is performed with
the Heating Roller temperature setting
changed to 174 °C.
[4] In standby state
Heating Roller temperature setting: 180 °C
[4]
4139T2E563AA