EVERY 900 HOURS

Air cleaner restriction indicator

1. Air cleaner restriction light indicates that air cleaner is
blocked.
2. Clean the air cleaner outer element whenever light
glows.
3. If the air cleaner restriction indicator illuminates contin-
uously, check the air cleaner restriction sensor. (1).
4. Disconnect the Electrical connection
5. Unscrew the air cleaner restriction sensor (2) from air
inlet pipe. Inspect the air cleaner restriction sensor.
Replace the air restriction sensor indicator if necessary.

Every 1200 hours

Transmission/hydraulics oil level

WARNING
Burn hazard!
Be very careful to avoid contact with hot fluids. If fluid is extremely hot, allow it to cool to a moderately
warm temperature before proceeding.
Failure to comply could result in death or serious injury.
1. Prior to changing oil, run the engine and operate the
hydraulic/transmission system until the oil is warm.
2. Park the tractor on level ground, lower the three point
linkage and stop the engine. Engage the parking brake
and block wheels.
7 - MAINTENANCE