Every 10 hours of operation or daily

Engine oil level

1. Before checking the oil level, ensure that the tractor is
on level ground, stop the engine and wait for a short
period to allow the oil to drain back into the sump.
2. Pull out the dipstick from dipstick port. (1) see figure 2
3. Check the oil level by means of the dipstick (1) see
figure 1.
4. If the level is below minimum mark, add fresh oil (1) see
figure 2 until oil level is between the two marks on the
dipstick.
NOTICE: Do not fill above the upper maximum line on dipstick. Excessive oil will be burned off within a short time
and give a false impression of oil consumption.

Engine cooling system

WARNING
Burn hazard!
Hot coolant can spray and scald if you remove the radiator or deaeration tank cap while the system
is hot. To remove the cap: allow the system to cool, turn the cap to the first notch, and wait for all
pressure to release. Remove the cap only after all pressure has released.
Failure to comply could result in death or serious injury.
7 - MAINTENANCE
7-13
1
GNIL14TR00519AA
2
GNIL14TR00523AA
W0367A