Annex notes1:
Test set
1. Test mode (Bch+Tch)
2. Cell power –85 dBm
HP8960
3. Cell band
4. Broadcast channel
5. Cable lose
1. Analyser/Generator
2. RF level used –85 dBm
CMU200
3. RF Channel
4. Transmission :
5. Cable lose
Annex notes2-1 : (AGC, AFC) Please Configure as follows (CMU200)
8 Change to GSM900 Analyser/Generator (Non-Signalling mode).
8 Change RF level Used TS –85 dBm and RF level Unused TS –20 dBm in Generator. Switch on Generator.
8 Change channel to ch62 in Generator (GSM850: ch190, GSM1800: ch699, GSM1900: ch662).
8 Change Transmission mode to "Continuous" as below.
AGC
1. Test mode (Bch+Tch)
2. Cell power –85 dBm
3. Cell band
4. Broadcast channel
5. Cable lose
1. Analyser/Generator
2. RF level used –85 dBm
Unused –20 dBm
3. RF Channel
4. Transmission :
Continuous
5. Cable lose
AFC
Unused –20 dBm
Continuous
– 8-23 –
APC
1. Test mode (Bch+Tch)
2. Cell power –85 dBm
3. Cell band
4. Cable lose
5. Broadcast channel
6. MS Tx level
1. Analyser/Generator
2. RF level used –85 dBm
Unused –20 dBm
3. RF Channel
4. Transmission: Burst
5. Cable lose
6. Bit modulation: Off