7.4. Test Equipment Setup
7.4.1. Equipment Required
GSM
Test Set
3.8 V
DC
Power
Test Set
3.8 V
DC
Power
IMPORTANT NOTE
To allow accurate measurement of the complete unit, the test equipment must be connected as shown.
For testing the handheld unit the following equipment is required:
1. PCB Repair Jig
2. Power Cable
3. Download Cable
4. RF Cable
5. 12 V power supply
6. Personal computer with RS232 interface and running Microsoft Windows
7. GSM test station
8. EB-X100 Service software
The EB-X100 Service software should be installed onto the main drive of the personal computer.
The RF cable is connected to the GSM test station via suitable adaptor. The 3.8 V supply is connected to the RF Adaptor and
PCB Repair Jig with power cable.
NOTE: A suitable test SIM card compatible with the GSM test station will be required.
RF Cable
Power Cable
GSM
RF Cable
Power Cable
COMPLETE UNIT TEST SETUP
Figure 7.6. : Test Connection Diagram
PCB Repair Jig
Data
PC
PCB TEST SETUP
Handset
RF Test
Data
PC
95, 98, XP or 2000
®