WARNING
NOTES:
1.) Y ENABLES HI SPD FAN COOLING
2.) E ENABLES LO SPD FAN HEATING
W2 AND OT2 CLOSED ENABLES HI SPD FAN HEATING
3.) OT1 PJ4 AND 0T2 PJ2 MUST BE CUT
FOR THIS CONFIGURATION
4.) DIP SWITCH #4 MUST BE IN THE "ON" POSITION.
5.) CUT HUM PJ6 JUMPER IF USING HUMIDISTAT.
STAT OPENS ON HUMIDITY RISE.
HEATPUMP - 2 STG EMHT 1 STG AUX - 1 OUTDOOR T'STAT
2 SPEED HEAT PUMP WITH SINGLE OR TWO STAGE HEATING
(OPTIONS FOR EMERGENCY HEAT) WITH CONVENTIONAL TWO STAGE THERMOSTAT
NOTES:
1.) Y ENABLES HI SPD FAN COOLING
2.) E ENABLES LO SPD FAN HEATING
4.) CUT HUM PJ6 JUMPER IF USING HUMIDISTAT
STAT OPENS ON HUMIDITY RISE
5.) DIP SWITCH #4 MUST BE IN THE "OFF" POSITION
Wiring is subject to change, always refer to the wiring diagram on the unit for the most up-to-date wiring.
HIGH VOLTAGE!
MULTIPLE POWER SOURCES MAY BE PRESENT. FAILURE TO DO SO
MAY CAUSE PROPERTY DAMAGE, PERSONAL INJURY OR DEATH.
OUTDOOR
THERMOSTAT
HEATPUMP
R
Y
C
O
W2
HEATPUMP
CONDENSER
R
YCON
COM
O
W2
ED
NO AUX HEAT IN HEATPUMP MODE UNTIL OUTDOOR T'STAT CLOSES
HEATPUMP
W2
W2
HEATPUMP - WITH 1 STG EMHT 1 STG AUX HEAT
DISCONNECT ALL POWER BEFORE SERVICING.
ROOM
THERMOSTAT
E
O
C
R
W2
THERMOSTATS
E\W1
W/W2
O
OTC
OT1
OT2
C
R
OUTDOOR
HEATPUMP
CONDENSER
R
YCON
COM
O
W2
ED
W1
W2
C
HEATER
24 VAC
W1
W2
OT1
OT2
HUM
PLEASE REFER
TO MANUAL
FOR PROPER
DIP SWITCH
(CFM)
CONFIGURATION.
O
W2
E\W1
O
OTC
OT1
OT2
OUTDOOR
W2
W1
W2
W1
W2
OT1
OT2
HUM
DI
P
PN. B1368274
5
G
Y
HUMIDISTAT
(OPTIONAL)
SEE NOTE 5
HUMIDISTAT
Y1
G
Y/Y2
HUM
REMOVE
PRODUCTION
WIRE Y1 - O
Y1
R
2nd STAGE HEATER
1st STAGE HEATER
HUMIDISTAT
(OPTIONAL)
SEE NOTE 4
HUMIDISTAT
REMOVE
HUM
PRODUCTION
WIRE Y1-O

Advertisement

loading