Goodman AEPF Supplemental & Opeating Instructions page 3

Hide thumbs Also See for AEPF:

Advertisement

WARNING
HEAT PUMP WITH SINGLE OR TWO-STAGE HEATING (OPTIONS FOR EMERGENCY HEAT)
NOTES:
1.) Y ENABLES HI SPD FAN COOLING
2.) E AND W2 ENABLE HI SPD FAN HEATING
3.) IF OT2 PJ2 JUMPER IS CUT E AND W2 ENABLE
LO SPD FAN HEATING
4.) DIP SWITCH #4 MUST BE IN THE "ON" POSITION.
5.) CUT HUM PJ6 JUMPER IF USING HUMIDISTAT.
STAT OPENS ON HUMIDITY RISE.
NOTES:
1.) Y ENABLES HI SPD FAN COOLING
2.) E ENABLES LO SPD FAN HEATING
W2 ENABLES HI SPD FAN HEATING
3.) OT1 PJ4 MUST BE CUT FOR THIS CONFIGURATION
4.) DIP SWITCH #4 MUST BE IN THE "ON" POSITION.
5.) CUT HUM PJ6 JUMPER IF USING HUMIDISTAT.
STAT OPENS ON HUMIDITY RISE.
Wiring is subject to change, always refer to the wiring diagram on the unit for the most up-to-date wiring.
HIGH VOLTAGE!
MULTIPLE POWER SOURCES MAY BE PRESENT. FAILURE TO DO SO
MAY CAUSE PROPERTY DAMAGE, PERSONAL INJURY OR DEATH.
HEATPUMP
R
Y
C
O
W2
HEATPUMP
CONDENSER
R
YCON
COM
O
W2
ED
HEATPUMP - WITH 1 STG EMHT 1 STG AUX HEAT
HEATPUMP
R
Y
C
O
W2
HEATPUMP
CONDENSER
R
YCON
COM
O
W2
ED
HEATPUMP - 2 STG EMHT 1 STG AUX HEAT
DISCONNECT ALL POWER BEFORE SERVICING.
ROOM
THERMOSTAT
E
W2
O
C
R
THERMOSTATS
E\W1
W/W2
O
OTC
OT1
OT2
C
R
OUTDOOR
HEATPUMP
CONDENSER
R
YCON
COM
O
W2
ED
W1
W2
C
HEATER
24 VAC
W1
W2
OT1
OT2
HUM
PLEASE REFER
TO MANUAL
FOR PROPER
DIP SWITCH
(CFM)
CONFIGURATION.
ROOM
THERMOSTAT
E
W2
O
C
R
THERMOSTATS
E\W1 W/W2
O
OTC
OT1
OT2
C
R
OUTDOOR
HEATPUMP
CONDENSER
R
YCON
COM
O
W2
ED
W1
W2
C
HEATER
24 VAC
W1
W2
OT1
OT2
HUM
PLEASE REFER
TO MANUAL
FOR PROPER
DIP SWITCH
(CFM)
CONFIGURATION.
3
G
Y
HUMIDISTAT
(OPTIONAL)
SEE NOTE 5
HUMIDISTAT
Y1
G
Y/Y2
HUM
REMOVE
PRODUCTION
WIRE Y1 - O
Y1
R
1st STAGE HEATER
G
Y
HUMIDISTAT
(OPTIONAL)
SEE NOTE 5
HUMIDISTAT
Y1
G
Y/Y2
HUM
REMOVE
PRODUCTION
WIRE Y1 - O
Y1
R
2nd STAGE HEATER
1st STAGE HEATER

Advertisement

loading