WARNING
NOTES:
1.) Y/Y2 ENABLES HI SPD FAN COOLING
2.) E/W1 ENABLES LO SPD FAN HEATING
E/W1 WITH OT CLOSED ENABLES HI SPD FAN HEATING
3.) OT1 PJ4 MUST BE CUT FOR THIS CONFIGURATION
4.) DIP SWITCH #4 MUST BE IN THE "ON" POSITION.
5.) CUT HUM PJ6 JUMPER IF USING HUMIDISTAT.
STAT OPENS ON HUMIDITY RISE.
COOLING ONLY - 2 STAGE HEAT (1st ROOM T'STAT & 2nd OT)
NOTES:
1.) Y/Y2 ENABLES HI SPD FAN COOLING
2.) E/W1 ENABLES LO SPD FAN HEATING
W/W2 WITH OT CLOSED ENABLES HI SPD FAN HEATING
3.) OT1 PJ4 MUST BE CUT FOR THIS CONFIGURATION
OT2 PJ2 MUST BE CUT FOR THIS CONFIGURATION
4.) DIP SWITCH #4 MUST BE IN THE "ON" POSITION.
5.) CUT HUM PJ6 JUMPER IF USING HUMIDISTAT.
STAT OPENS ON HUMIDITY RISE.
COOLING ONLY - 2 STAGE HEAT (T'STAT ENABLED OT)
Wiring is subject to change, always refer to the wiring diagram on the unit for the most up-to-date wiring.
HIGH VOLTAGE!
DISCONNECT ALL POWER BEFORE SERVICING.
MULTIPLE POWER SOURCES MAY BE PRESENT. FAILURE TO DO SO
MAY CAUSE PROPERTY DAMAGE, PERSONAL INJURY OR DEATH.
OUTDOOR
THERMOSTAT
CONDENSING
UNIT
E\W1
W/W2
CONDENSER
R
YCON
COM
PLEASE REFER
TO MANUAL
FOR PROPER
DIP SWITCH
CONFIGURATION.
1st STAGE ENABLED THRU ROOM T'STAT
2nd STAGE ENABLED THRU CLOSED OT
OUTDOOR
THERMOSTAT
CONDENSING
UNIT
E\W1
W/W2
CONDENSER
R
YCON
PLEASE REFER
TO MANUAL
FOR PROPER
DIP SWITCH
CONFIGURATION.
1st STAGE ENABLED THRU ROOM T'STAT
2nd STAGE ENABLED THRU ROOM T'STAT AND CLOSED OT2
ROOM
THERMOSTAT
W
C
R
G
Y
THERMOSTATS
O
OTC
OT1
OT2
C
R
Y1
G
Y/Y2
OUTDOOR
HEATPUMP
O
W2
ED
Y1
W1
W2
C
R
HEATER
24 VAC
W1
W2
OT1
OT2
HUM
(CFM)
2nd STAGE HEATER
1st STAGE HEATER
ROOM
THERMOSTAT
C
R
G
Y
W1
W2
THERMOSTATS
O
OTC OT1
OT2
C
R
Y1
G
OUTDOOR
HEATPUMP
Y1
COM
O
W2
ED
W1
W2
C
R
HEATER
24 VAC
W1
W2
OT1
OT2
HUM
(CFM)
2
HUMIDISTAT
(OPTIONAL)
SEE NOTE 5
HUMIDISTAT
HUM
HUMIDISTAT
(OPTIONAL)
SEE NOTE 5
HUMIDISTAT
Y/Y2
HUM
2nd STAGE HEATER
1st STAGE HEATER

Advertisement

loading