Refer to Service Manual RS6200006 for installation, operation & troubleshooting information.
All safety information must be followed as provided in the Service Manual.
Refer to the appropriate Parts Catalog for part number information.
Models listed on page 3.
This manual is to be used by qualified, professionally trained HVAC technicians only. Goodman
does not assume any responsibility for property damage or personal injury due to improper
service procedures or services performed by an unqualified person.
AVPTC Air Handlers
Copyright © 2013-2014 Goodman
AL
AL
AL
AL
Manufacturing Company, L.P.
RT6121004r2
March 2014

Advertisement

Table of Contents
loading

Summary of Contents for Goodman AVPTC24B14A

  • Page 1 Refer to the appropriate Parts Catalog for part number information. • Models listed on page 3. This manual is to be used by qualified, professionally trained HVAC technicians only. Goodman RT6121004r2 does not assume any responsibility for property damage or personal injury due to improper March 2014 service procedures or services performed by an unqualified person.
  • Page 2: Product Identification

    Disconnect ALL power before servicing or installing this unit. Multiple power sources may be present. Failure to do so may cause property damage, personal injury or death. Installation and repair of this unit Goodman will not be responsible WARNING WARNING WARNING...
  • Page 3 WARNING that is not design certified by damage, personal injury, or death, Goodman for use with this unit. do not store combustible materials or use gasoline or Serious property damage, personal injury, reduced unit other flammable liquids or vapors in the vicinity of this performance and/or hazardous conditions may result appliance.
  • Page 4: Product Design

    PRODUCT DESIGN Heating and cooling equipment located in garages, which may generate a glow, spark or flame capable of igniting If this appliance is installed in WARNING WARNING flammable vapors, must be installed with the ignition source an enclosed area such as a at least 18"[46cm] above the floor level.
  • Page 5: Product Dimensions

    AVPTC PRODUCT DIMENSIONS...
  • Page 6: Product Specifications

    PRODUCT DIMENSIONS AVPTC M odel A VPT C 24B14 * A VPT C 30C 14* A VPT C 36C 14* A VPT C 48C 14* A VPT C 42D14* A VPT C 48D14* A VPT C 60D14* PRODUCT SPECIFICATIONS AVPTC AVPTC AVPTC AVPTC...
  • Page 7: Blower Performance Data

    BLOWER PERFORMANCE DATA Speed Selection Dip Switches Cooling/Heat Pump Airflow Table Low stage High sta ge Cool Adjust Profile Model Speed tap Continuous (CFM) (CFM) Selection Selection Selection Switches Switches Switches Speed AVPTC24B14** OFF OFF OFF OFF OFF 1125 OFF ON AVPTC30C14** 1020 1225...
  • Page 8 HEAT KIT INFORMATION AVPTC ELECTRIC HEAT AIRFLOW TABLE † †† ††† AVPTC42D14A* AVPTC48D14A* AVPTC60D14A* Htr kW 11 AVPTC24B14A* AVPTC30C14A* AVPTC36C14A* AVPTC48C14* 850** 1250 1250 1250 ON OFF 1300 1300 1300 ON OFF ON 1000 1000 1500 1500 1500 ON OFF OFF...
  • Page 9: Wiring Diagrams

    WIRING DIAGRAMS AVPTC HIGH VOLTAGE! DISCONNECT ALL POWER BEFORE SERVICING OR INSTALLING THIS UNIT. MULTIPLE POWER SOURCES MAY BE PRESENT. FAILURE TO DO SO MAY CAUSE PROPERTY DAMAGE, PERSONAL INJURY OR DEATH. COLOR CODES: HTR1 HTR2 PK ---- PINK HTR1 HTR1 HTR2 BR ---- BROWN...
  • Page 10 WIRING DIAGRAMS AVPTC HIGH VOLTAGE! DISCONNECT ALL POWER BEFORE SERVICING OR INSTALLING THIS UNIT. MULTIPLE POWER SOURCES MAY BE PRESENT. FAILURE TO DO SO MAY CAUSE PROPERTY DAMAGE, PERSONAL INJURY OR DEATH. 3-Phase Heat Kit CIRCUIT 1 NOTE: WHEN INSTALLING HEATER KIT, ENSURE SPEED TAP MUST EXCEED OR EQUAL 1 PH 208-240V THE MINIMUM BLOWER SPEED (MBS) SPECIFIED FOR THE AIRHANDLER/HEATER KIT COMBINATION ON THIS UNIT'S SERIAL PLATE.