Feature Menus; Menu #1 - Basic Features - Clarion SR1000 Installation Manual

Clarion sr1000 cctv systems: installation guide
Hide thumbs Also See for SR1000:
Table of Contents

Advertisement

The module programming routine will be exited if:
The door is closed.
The ignition is turned on.
The override switch is pressed too many times.
More than 15 seconds elapses between programming steps.
One long siren chirp indicates that the module programming routine has been exited.

feature menus

The default settings are indicated in bold type. Features that have additional settings that can be pro-
grammed using the Pro Security Programmer are indicated with an asterisk (*).

menu #1 - basic features

FEATURE NUMBER
1-1
1-2
1-3
1-4
1-5
1-6
1-7
1-8
1-9
1-10
1-11
ONE-CHIRP SETTING (DEFAULT)
Active arming
Arm/disarm chirps ON
Ignition lock ON*
Ignition unlock ON
Active locking only
Panic with ignition ON
0.8 second door lock pulses
Forced passive arming ON
Automatic engine disable ON
Armed When Driving (AWD) ON
Anti-code grabbing ON
TWO-CHIRP SETTING
Passive arming
Arm/disarm chirps OFF
Ignition lock OFF*
Ignition unlock OFF
Passive locking
No panic with ignition ON
3.5 second door lock pulses
Forced passive arming OFF
Automatic engine disable OFF
AWD OFF
Anti-code grabbing OFF

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents