Rfid gate sensor

Advertisement

Quick Links

12-24V
GREEN
GND
BROWN
COM
WHITE
NO
YELLOW
NC
GREY
COM
PINK
NO
VIOLET
NC
BLACK
45°
30°
>
2.8 m
<
2.8 m
POWER-
SUPPLY
START-
SIGNAL
STOP-
SIGNAL
15°
-
+
1
4
0
CONDOR ID
QUICK GUIDE
RFID GATE SENSOR
START
STOP
RED-GREEN
RED-GREEN
At the end of the installation or
after changing the adjustment of
the sensor,it is MANDATORY to
introduce the preset value
in function of the installation
height by remote control.
FOR THIS, THE IR-FIELD
MUST BE EMPTY!
See user's guide on the
next pages for more
detailed information.
P.3
p.3
p.3
OFF
P.4
p.4

Advertisement

Table of Contents
loading

Summary of Contents for BEA CONDOR ID

  • Page 1 CONDOR ID QUICK GUIDE RFID GATE SENSOR 12-24V GREEN POWER- BROWN SUPPLY WHITE START- YELLOW SIGNAL GREY STOP- PINK SIGNAL VIOLET BLACK 45° 30° 15° START STOP > 2.8 m < 2.8 m RED-GREEN RED-GREEN At the end of the installation or...
  • Page 2: Installation Tips

    CONDOR ID USER’S GUIDE RFID GATE SENSOR DESCRIPTION Fixing screw Adjustment screw for radar tilt angle Infrared lenses Radar antenna LED-SIGNAL GREEN LED RED LED RED-GREEN LED START-SIGNAL STOP-SIGNAL SETUP LED FLASHES LED FLASHES LED OFF QUICKLY SLOWLY INSTALLATION TIPS...
  • Page 3 DETECTION FIELD The Spotfinder is necessary to position the detection field correctly. The CONDOR ID should be positioned by using the Spotfinder so that the START-line is at the desired distance from the sensor. Therefore the Spotfinder should be put on the floor and turned towards the sensor.
  • Page 4: Frequency Adjustment

    REMOTE CONTROL PRESETTINGS Installation height <2.8m >2.8m Max. duration of presence detection IR-Immunity Detection field size Rejection mode Holdtime STOP-Relay RFID-mode Relay configuration At the end of the installation or after changing the adjustment of the sensor,it is MANDATORY to introduce the preset value in function of the installation height by remote control.
  • Page 5: Remote Control

    REMOTE CONTROL How to adjust one or more parameters? Select parameter Set value How to check one or more values? Select parameter X value GREEN The number of green flashes indicates the value of the chosen parameter. SETTINGS OVERVIEW RFID-mode Holdtime STOP-Relay radar + IR seperately 0 ms...
  • Page 6: Troubleshooting

    TROUBLESHOOTING SYMPTOMS POSSIBLE CAUSES CORRECTIVE ACTION During setup the LED The power supply is too weak. Make sure the power supply is continues to flash stable. quickly red-green. RED-GREEN High intensity light (discharge During setup the LED Change the position of the lamps. lamps) disturbs the sensor.
  • Page 7: Technical Specifications

    TECHNICAL SPECIFICATIONS Technology: microwave and infrared Radiated frequency: 24.175 GHz Radiated power density: << 5mW/cm Transmitter radiated power: < 20 dBm EIRP Detection mode: motion and presence LED-signal: green, red Supply voltage: 12 - 24V AC +10% / -10% (measured at cable end) 12 - 24V DC +10% / - 3% Mains frequency: 50 - 60 Hz...