Possible cause
Defective PE shelf
Action
Unseat the affected trunk card and enable the TN.
If you do not receive an OVD message, test superloop TNs by entering:
LD 30
UNTT l s c u
Test TNs on other loops by entering:
LD 45
TEST
If you receive an OVD message, replace the card cage assembly in the
module.
Clearing trunk faults
Meridian 1 Fault clearing