7. Thread this pipeline through the wall and
connect it to the outdoor unit.
8. Insulate all the piping, including the valves of the
outdoor unit.
9. Open the stop valves of the outdoor unit to start
the flow of the refrigerant between the indoor
and outdoor unit.
CAUTION
Check to make sure there is no refrigerant leak
after completing the installation work. If there is a
refrigerant leak, ventilate the area immediately and
evacuate the system (refer to the Air Evacuation
section of this manual).
Installation Of The Throttle. (Some Models)
1
2
3
1 Throttle
2 Liquid pipe
3 Gas pipe
Page 19-GB
Precautions
● For ensuring throttled efficiency, please mount
the throttle as horizontally as possible.
Indoor
Indoor
Indoor
● Wrap the supplied anti-shock rubber at
external of the throttle for denoise.
1 Anti-shock rubber
2 Throttle
Outdoor
Outdoor
Outdoor