Outdoor Uint Wiring - Carrier Super-Slim 18-24 Installation Manual

Table of Contents

Advertisement

Available languages

Available languages

Indoor unit power wires
Outdoor unit
Indoor & Outdoor connective
wires (purchased seperately)
(C)
Air switch
(purchased seperately)
Indoor unit power wires
Outdoor unit power wires
Outdoor unit
Indoor & Outdoor connective
wires (purchased seperately)
(D)
(Only for the North American)
Air switch
(purchased seperately)
Outdoor unit power wires
Outdoor unit
Air switch
(purchased seperately)
NOTE: The cographs are for explanation purpose
only. Your machine may be slightly dierent. The
actual shape shall prevail.
Page 21-GB
Air switch
(purchased
seperately)
Indoor unit
Air switch
(purchased seperately)
Indoor unit
Indoor & Outdoor connective
wires (purchased seperately)
Indoor unit
Outdoor Unit Wiring
WARNING
Before performing any electrical or wiring work,
turn off the main power to the system.
1. Prepare the cable for connection
a. You must first choose the right cable size. Be
sure to use H07RN-F cables.
NOTE: In North America, choose the cable
type according to the local electrical codes and
regulations.
Minimum Cross-Sectional Area of Power and
Signal Cables (For reference)
Rated Current of
Appliance (A)
> 3 and ≤ 6
> 6 and ≤ 10
> 10 and ≤ 16
> 16 and ≤ 25
> 25 and ≤ 32
> 32 and ≤ 40
CHOOSE THE RIGHT CABLE SIZE
The size of the power supply cable, signal cable,
fuse, and switch needed is determined by the
maximum current of the unit. The maximum
current is indicated on the nameplate located on
the side panel of the unit. Refer to this nameplate
to choose the right cable, fuse, or switch.
NOTE: In North America, please choose the
right cable size according to the Minimum Circuit
Ampacity indicated on the nameplate of the unit.
b. Using wire strippers, strip the rubber
jacketfrom both ends of the signal cable to
reveal approximately 15cm (5.9") of wire.
c. Strip the insulation from the ends.
d. Using a wire crimper, crimp u-lugs on the
ends.
NOTE: When connecting the wires, strictly follow
the wiring diagram found inside the electrical box
cover.
Nominal Cross-
Sectional Area (mm²)
0.75
1
1.5
2.5
4
6