Download Print this page
Carrier Infinity 19VS Owner's Manual
Carrier Infinity 19VS Owner's Manual

Carrier Infinity 19VS Owner's Manual

Variable speed air conditioner with puron refrigerant

Advertisement

Quick Links

24VNA9
Infinity® 19VS Variable Speed Air Conditioner
with Puron® Refrigerant
A NOTE ABOUT SAFETY
Any time you see this symbol
unit, be aware of the potential for personal injury. There are three levels
of precaution:
WARNING signifies hazards that could result in personal injury or
death.
CAUTION is used to identify unsafe practices which would result in
minor personal injury or product and property damage.
NOTE is used to highlight suggestions which will result in enhanced
installation, reliability, or operation.
WARNING
!
PERSONAL INJURY, DEATH AND / OR PROPERTY
DAMAGE HAZARD
Failure to follow this warning could result in personal injury, death or
property damage.
Improper installation, adjustment, alteration, service, maintenance, or
use can cause explosion, fire, electrical shock, or other conditions
which may cause personal injury or property damage.
qualified installer, service agency, or your distributor or branch for
information or assistance. The qualified installer or service agency
must use factory-authorized kits or accessories when modifying this
product.
Read and follow all instructions and warnings, including labels shipped
with or attached to unit before operating your new air conditioner.
ABOUT YOUR AIR CONDITIONING SYSTEM
Our products are designed, tested and built in accordance with US
Department of Energy standardized procedures and other standards;
however, actual operating results and efficiencies may vary based on
manufacturing and supplier tolerances, equipment configuration,
operating conditions and installation practices.
Identifying Your System
Your new Carrier cooling system is what we call a "split system." It has
an outdoor unit and an indoor unit connected to each other with copper
tubing called refrigerant lines. Each of these units has a rating plate with
the model and serial numbers you will need to reference when calling an
authorized Carrier dealer about your system.
Take a few moments now to locate those numbers and record them in the
spaces provided on the cover of this booklet.
USING YOUR NEW CARRIER SYSTEM
Your air conditioning system is controlled by a wall-mounted Infinity
Touch Control or thermostat installed inside your home. See the Infinity
Touch or thermostat Homeowner Guide for more details on system
operation.
INFINITY VARIABLE SPEED OPERATION
You may notice your system runs for longer periods of time. This
system is designed to meet the cooling needs of the home at a wide range
of conditions. Your indoor temperature will remain more consistent with
fewer drafts, better humidity control, enhanced comfort and enhanced
energy efficiency.
Owner's Manual
in manuals, instructions and on the
Consult a
COOLING YOUR HOME
For cooling operation, make sure the System or Mode control is set to
the appropriate mode. Then, adjust the Temperature control to your
desired setting. Finally, use the Fan control to select Automatic or On
(runs continuously).
OPERATION UNDER EXTREME CONDITIONS
Your air conditioner will run as long as necessary to maintain the indoor
temperature selected on your Infinity Touch Control or thermostat. On
extremely hot days, your air conditioner will run for longer periods at a
time than on moderate days. Your system will also run for longer
periods of time under the following conditions:
• Frequent opening of exterior doors
• Operating laundry appliances
• Taking hot showers
• More than the usual number of people present in the home
• More than the normal number of electric lights in use
• Drapes or blinds are open on the sunny side of the home
Your new Infinity 19VS air conditioner is different from most cooling
systems. Because this is a variable speed system, it is designed to operate
at different speeds depending on the temperature and humidity
conditions. You may notice the sound coming from the outdoor unit
changing from time to time depending on the weather conditions. The
higher speed produces a higher sound. This change of speed allows the
system to operate more efficiently and maintain comfortable conditions
inside the home as the outdoor temperature rises. You may also hear a
slight hissing sound when near the outdoor unit in the off-cycle. This is
the sound of system pressure equalization which is required to enable
soft and easy starting of the next cycle. These sounds are normal and do
not represent a problem with your system.
ROUTINE MAINTENANCE
Simple, routine maintenance as described below will enhance your air
conditioner system's ability to operate economically and dependably.
Always remember the following safety precautions:
!
CUT HAZARD
Failure to follow this warning could result in personal injury.
Although special care has been taken to minimize sharp edges in the
construction of your unit, be extremely careful and wear appropriate
protective clothing and gloves when handling parts or reaching into the
unit.
WARNING
!
ELECTRICAL SHOCK HAZARD
Failure to follow this warning could result in personal injury or death.
Before installing, modifying, or servicing system, main electrical
disconnect switch must be in the OFF position. There may be more than
1 disconnect switch. Lock out and tag switch with a suitable warning
label.
NOTE: There may be more than one electrical disconnect switch.
SOUND
CAUTION

Advertisement

loading

Summary of Contents for Carrier Infinity 19VS

  • Page 1 Identifying Your System conditioner system’s ability to operate economically and dependably. Your new Carrier cooling system is what we call a ”split system.” It has Always remember the following safety precautions: an outdoor unit and an indoor unit connected to each other with copper tubing called refrigerant lines.
  • Page 2 • Level Installation comfort system should be inspected regularly by a properly trained Your Carrier dealer will install the outdoor unit in a level position. If the service technician. Many dealers offer this service at a reduced rate with support base settles or shifts and the unit is no longer level, be sure to a service contract.

This manual is also suitable for:

24vna9