3.4 Operation with Joystick-Type SIDs

Driving is via the SID's joystick and the User Switch is used to
enter the User Menu.
These include Joystick Throw, Joystick Orientation and Joystick
Deadband. Refer to your health care professional or servicing
agent.
Standard control of seating movement is via Forward and
Reverse commands, and Left and Right commands will select a
different seat axis for movement.
If required, it is possible to re-program the OMNI2 to control
the seating movement in alternative ways. Refer to your health
care professional or servicing agent.
For latched operation using this SID type, refer to section
Latched Operation.

3.5 Operation with Switch-Type SIDs

Driving is via the SID's Forward, Reverse, Left and Right
switches, and the Fifth Switch or User Switch is used to enter
the User Menu.
There are several standard R-net programming features that
may be useful when using this SID type. These include Joystick
Orientation. Refer to your health care professional or servicing
agent.
Standard control of seating movement is via Forward and
Reverse commands, and Left and Right commands will select a
different seat axis for movement.
If required, it is possible to re-program the OMNI2 to control
the seating movement in alternative ways. Refer to your health
care professional or servicing agent.
For latched operation using this SID type, refer to section
Latched Operation.
OMNI2
Rev.A
3.6 Operation with 3-Axis Proportional and Switch-
Type SIDs (Head Arrays)
These types of SID contain a Forward/Reverse command, Left
and Right commands, as well as a User Switch(es)*. Driving is
via the Forward/Reverse, Left and Right commands
* Depending on the installation, as well as a normally-closed
User Switch, there may be a User Switch integrated into the
head array. This switch would connect to the OMNI2 via the
Fifth Switch pin on the D-type connector.
User Switch commands are then used to change drive
direction and to enter the User Menu.
There are 3 ways to program the OMNI2 to provide this
functionality.

3.6.1 Double Click Change

A single User Switch operation toggles the direction, while a
double operation of the User Switch will enter the User Menu
or sequence the other functions.
This method is selected by setting Fwd / Rev Auto Toggle to
Off.
There is programmability associated with the timing of the
double operations.
Refer to your health care professional or servicing agent.

3.6.2 Auto Toggle Change

A direction change will occur if a Forward/Reverse command
is operated and released. A further operation of the Forward/
Reverse command will result in drive in the newly-selected
direction.
This sequence must be completed within a given time period,
typically 2 seconds. However, the parameter Auto Toggle Time,
can be adjusted to give a different time period. Refer to your
health care professional or servicing agent.
If the sequence is not completed within the time period, the
selected direction will automatically revert to its previous
state.
The User Switch is used to enter the User Menu.
This method is selected by setting Fwd/Rev Auto Toggle to On.
Refer to your health care professional or servicing agent.