Setup

Setup
1.
Install hose to spray gun and tighten
securely.
2.
Engage trigger lock.
Trigger lock engaged
1
Trigger lock disengaged
2
3.
Remove Tip Guard.
4.
Screw inlet strainer to bottom of suction
hose and hand tighten securely.
7.
Check hydraulic oil level. Add only Graco
Hydraulic Oil, ISO Grade 46, 169236 (5
gallon/18.9 liter) or 207428 (1 gallon/3.8
liter). Hydraulic tank capacity is 1.25
gallon (4.75 liters).
10
ti22698a1
1
2
ti03966a
5.
When spraying texture, remove inlet
strainer and filter bowl screen.
ti8692a
6.
Fill throat packing nut with TSL to
prevent premature packing wear. Do this
each time you spray.
ti18418b
ti18418a
3A4401A