8.
Disengage trigger lock.
Trigger lock engaged
1
Trigger lock disengaged
2
9.
Hold gun against grounded metal
flushing pail. Trigger gun and increase
fluid pressure slowly until pump runs
smoothly.
FLUSH
High-pressure spray is able to inject toxins
into the body and cause serious bodily
injury. Do not stop leaks with hand or rag.
3A4401A
1
2
ti03966a
10. Inspect fittings for leaks. If leaks occur,
turn sprayer OFF immediately. Perform
Pressure Relief Procedure, page 11.
Tighten leaky fittings. Repeat Startup
procedure steps 2-8. If no leaks,
continue to trigger gun until system is
thoroughly flushed.
11. Place displacement pump in paint pail.
12. Trigger gun again into flushing fluid pail
until paint appears.
13. Assemble Tip and Guard, page 14.
Startup
ti9695a
ti18248a
13