Clean Up
8.
Raise displacement pump above
flushing fluid and run sprayer for 15 to 30
seconds to drain fluid. Turn hydraulic
valve OFF. Turn engine OFF or turn
electric motor OFF and unplug.
9.
Engage trigger lock.
18
ti25424a
ti8692a
10. Unscrew and remove inlet strainer.
Clean and replace strainer if necessary.
11. If flushing with water, flush again with
mineral spirits, or Pump Armor, to leave
a protective coating to prevent freezing
or corrosion.
12. Wipe sprayer, hose and gun with a rag
soaked in water or mineral spirits.
ti18418a
ti2776a
3A4401A