Sine-Wave Filter - Siemens SINAMICS G120 Hardware Installation Manual

Power module
Hide thumbs Also See for SINAMICS G120:
Table of Contents

Advertisement

Spare parts and accessories
8.3 Optional accessories
8.3.4

Sine-wave filter

The sine-wave filter at the converter output limits the voltage rate of rise and the peak voltages
at the motor winding. The maximum permissible length of motor feeder cables is increased to
300 m.
The following applies when using a sine-wave filter:
• Operation is only permissible with pulse frequencies from 4 kHz to 8 kHz.
• The converter power is reduced by 5%.
• The maximum output frequency of the converter is 150 Hz at 380 V to 480 V.
• Operation and commissioning may only be performed with the motor connected, as the sine-
wave filter is not no-load proof.
• An output reactor is superfluous.
Dimensions and drilling patterns
Figure 8-8
Mounting position
Figure 8-9
76
Dimensions - footprint filter
Mounting position - footprint filter
Hardware Installation Manual, 04/2021, A5E36265179B-AB
PM250 Power Module

Advertisement

Table of Contents
loading

This manual is also suitable for:

Pm250

Table of Contents