RH-9
System Module & UI
6
VDD
VDDI
1
7
VDD
VDD
2in
8
VLCD-
VOUT
out
Baseband – RF interface
Signal name
From
RFICCNTRL (2:0)
RFBUSEN1X
UPP
RFBUSDA
UPP
RFBUSCLK
UPP
Clock
RFCLK
MJOE
LNER
RFCONV (9:0)
RXIINP
MJOE
LNER
Page 12
VDD digital
power supply
Booster
power supply
Booster out-
put
Table 12: BB – RF interface description
To
Parameter
MJOELNER control bus
MJOEL-
Logic "1"
NER
Logic "0"
MJOEL-
Logic "1"
NER
Logic "0"
MJOEL-
Logic "1"
NER
Logic "0"
System clock for phone
UPP
Frequency
Signal ampli-
tude
Duty cycle
(Mjoelner
spec.)
RF / BB analogue signals
UEM
Voltage swing
DC level
I/Q amplitude
mismatch
I/Q phase mis-
match
Data clock rate
ãNokia Corporation
CCS Technical Documentation
1.6
1.8
2.0
2
0
2.6
2.7
2.9
3
8
12
Min.
Typ.
Max.
1.38
-
1.80
0
-
0.4
1.38
-
1.80
0
-
0.4
1.38
-
1.80
0
-
0.4
-
26
-
0.3
1
1.37
6
40
-
60
1.35
1.4
1.45
1.3
1.35
1.4
-
-
0.2
-5
-
5
-
-
13
V
V
V
Decoupled to
GND on main
PWB with 1uF
Unit
Notes
V
RF Chip select
V
V
RF serial control
bus (bi-direc-
V
tional)
V
RF bus clock
V
MHz
System clock
UPP minimum
Vpp
recommended
amplitude is
0.3Vpp.
%
Waveform: Sinus/
triangle
V
Positive in-phase
Rx signal
V
dB
Deg.
MHz