Mounting

This section provides mounting information on the DVC RGB-HD A. See
for available Extron mounting kits and ordering information.

Mounting Options

The DVC RGB-HD A can be mounted to a rack, attached under a desk or podium, or
placed on a table top.
To mount the DVC using an Extron mounting kit, see the instructions provided with the kit.

UL Guidelines for Rack Mounting

The following Underwriters Laboratories (UL) guidelines pertain to the installation of the
DVC RGB-HD A in a rack:
Rack mounting — Attach the DVC to a standard 19-inch, 6-inch, or 3.5-inch rack
shelf (see the instructions provided with the mounting kit to rack mount the DVC).
Under-furniture mounting — Mount the DVC under the surface of a desk,
table, or podium. The Extron Under-desk Mounting Kit is provided with the
DVC RGB-HD A (see
Mounting under Furniture
Free-standing — Attach the four rubber feet to the bottom of the DVC in the four
corners and place the unit on furniture as desired.
Elevated operating ambient temperature — If the equipment is installed in a closed
or multi-unit rack assembly, the operating ambient temperature of the rack environment
may be greater than room ambient temperature. Therefore, consider installing the
equipment in an environment compatible with the maximum ambient temperature (TMA)
specified by the manufacturer.
Reduced air flow — Install the equipment in the rack so that the amount of air flow
required for safe operation of the equipment is not compromised.
Mechanical loading — Mount the equipment in the rack so that uneven mechanical
loading does not create a hazardous condition.
Circuit overloading — When connecting the equipment to the supply circuit, consider
the effect that circuit overloading might have on overcurrent protection and supply
wiring. Consider equipment nameplate ratings when addressing this concern.
Reliable earthing (grounding) — Maintain reliable grounding of rack-mounted
equipment. Pay particular attention to supply connections other than direct connections
to the branch circuit (such as the use of power strips).
www.extron.com
on the next page).