Error Responses
When the DVC receives a valid command, it executes the command and sends a response
to the host device. If the unit is unable to execute the command because the command
contains invalid parameters, it returns an error response to the host. The responses include:
— Invalid input number
•
E01
•
— Invalid command
E10
•
— Invalid parameter
E13
— Not valid for this configuration
•
E14
•
— Invalid command for signal type
E17
Using the Command and Response Table
The
Command and Response Table for SIS
the commands that the DVC RGB-HD A converter recognizes as valid, the responses that
are returned to the host, a description of the command function or the results of executing
the command, and command examples.
NOTE: If the unit does not support or recognize a command that is entered, no action is
taken and no response is returned.
Space
Figure 9.
NOTE: Upper- and lowercase text can be used interchangeably.
ASCII to Hex Conversion Table
ASCII to Hexadecimal Character Conversion Table
DVC RGB-HD A • Remote Configuration and Control
Commands, beginning on page 15, lists
•