Open the supply shut-off valve and
check all connections for leakage. If
the connections have been properly
assembled, a slight retightening of the
nuts should stop any leakage.
If the toilet is leaking between the tank
and the bowl, carefully retighten the
three brass nuts evenly. Periodically
check all the bowl and tank
connections for leakage for several
days following installation.
Install the toilet seat according to the
seat manufcture's installation
instructions.
FILL FLOAT WITH
BALLAST
Test flush the toilet.
Periodically check all connections for
leaks for several days following
installation.
Set the tank cover in place on the tank.
MINOR ADJUSTMENT OF

WATER LEVEL

Move the snap along "OPEN" direction.
To lower water level: Move water cup
down to a proper height and rotate
screw anticlockwise to achieve the
desired water level. (Refer to float
adjustment instructions.)
To elevate water level: Rotate screw
clockwise and raise float to the desired
water level. Elevate water cup to a
proper position as well. (Refer to float
adjustment instructions.)
1033003-T01-N
Fig.#9
9
Fill Valve Cap
Float
Fig.#10
10
Snap
Fig.#11a
11a
Screw
Fig.#11b
11b
Fig.#11c
11c
OPEN